1 、Applicable scope
HLR3800-3G3D single-phase motor (compressor) the starting relay mainly uses in exchanging 50/60HZ, the voltage to the 277V control circuit and the nominal current to the 16A power circuit, through starts the electric capacity, the starting single-phase motor (compressor). Is suitable in the air conditioning, the refrigerator and so on industry machine electric appliance equipment and so on domestic electric appliances and water pump.
|
2 、Type and meaning
|
HLR |
3800 |
- |
3 |
|
G |
3 |
D |
relay |
serial |
bulk pack |
Coil No. |
50Hz |
Operating characteristics |
Operating Position |
Terminal configuration |
|
2.Product explanation and major technique parameter
|
★ Fixed isolation voltage Ui : 600V |
★ Fixed working voltage Ue : AC 277V |
★ Fixed operating current: Ie=16A , Ith=35A |
★ Normal connection and breaking current: 35A 、Breaking current ability: 96A |
★ Mechanical life> 1,000,000 times |
★ Electricity life> 100,000 times |
★ Coil working voltage scope: 70% ~110%Us |
★ Product coil working voltage Us=AC 170 ~ 502V
|
★ The relay winding (cold clean criticality) can attract reliably in AC 170 ~ 502V gathers, the released voltage is not lower than AC 40V. |
|
3.Conforms To The Standard |
|